CP1500PFCLCDTAA

TAA UPS Systems


CP1500PFCLCDTAA | TAA UPS Systems
Federal Trade Agreements Act (TAA) compliant power protection

Product Overview


The CyberPower PFC Sinewave CP1500PFCLCDTAA is a mini-tower UPS with line interactive topology. It complies with the U.S. Trade Agreement Act (TAA). This model provides battery backup, power protection (using sine wave output) and surge protection for desktop computers, workstations, networking devices, and home entertainment systems requiring active PVC power source compatibility. The CP1500PFCLCDTAA uses Automatic Voltage Regulation (AVR) to correct minor power fluctuations without switching to battery power, which extends battery life. AVR is essential in areas where power fluctuations occur frequently.

Two USB charge ports (1 Amp shared) power portable devices such as mobile phones, MP3 players, and cameras. This model comes with a three-year warranty (including coverage of batteries) and a $500,000 Connected Equipment Guarantee.

  • Battery Backup
    Supplies power long enough for equipment to properly shut down when utility power fails. Helps prevent loss of data and minimizes the component stress caused by a hard shutdown.
  • Surge Protection
    Diverts excess voltage away from sensitive electronic equipment during an AC power surge or power spike to prevent damage.
  • Data Line Protection
    Prevents power surges that travel through telephone, coaxial, and Ethernet lines from causing damage to electronics.
  • Line Interactive Topology
    Exists when a line interactive UPS has an autotransformer that regulates low voltages (e.g., brownouts) and over voltages (e.g., spikes) without having to switch to battery.
  • Automatic Voltage Regulation (AVR)
    Provides clean, consistent AC power by automatically increasing (boosting) low voltage without using battery power when incoming utility power experiences minor fluctuations.
  • Sine Wave Output
    Provides power protection to ENERGY STAR® 6.0 systems with Active PFC power supplies.
  • USB Charge Ports
    Chrge and power USB devices such as tablets (including iPad), smartphones, MP3 players, and other mobile accessories.
  • GreenPower UPS™ Bypass Design
    Is a patented design that allows utility power to bypass the UPS transformer, when AC power is stable, which reduces energy consumption, noise, and heat buildup.
  • Multifunction LCD Panel
    Displays immediate, detailed information on the UPS battery and power conditions, alerting users to potential problems before they can affect critical equipment and cause downtime.
  • Ultra Quiet Design
    Minimizes noise during operation for a quieter work environment.
  • PowerPanel® Personal Edition Software
    Provides a user-friendly dashboard interface for controlling and monitoring the UPS. Free software download available. See the Resources tab.
  • Cisco Compatible
    This CyberPower UPS system is a Cisco EnergyWise compliant end device.
  • ENERGY STAR
    This model is an ENERGY STAR® certified Uninterruptible Power Supply (UPS) system. ENERGY STAR is the trusted, government-backed symbol for energy-efficient products and practices that help save money and protect the environment.
  • Three-Year Warranty
    CyberPower will repair or replace a defective UPS system (including batteries) within three years of the purchase date. See warranty for details.
  • Connected Equipment Guarantee
    CyberPower will repair or replace properly connected equipment if it is damaged by a power surge.
CP1500PFCLCDTAA | TAA UPS Systems
Federal Trade Agreements Act (TAA) compliant power protection
General
UPS Topology Line Interactive
Energy Saving GreenPower UPS™ Bypass Technology
Active PFC Compatible Yes
Input
Voltage 90 – 139 VAC
Frequency 57 – 63 Hz
Plug Type NEMA 5-15P
Plug Style Right Angle, 45° Offset Right
Cord Length 5 ft
Adjustable Voltage Range 78 – 142 VAC
Automatic Voltage Regulation (line mode) 12%
Output
VA 1,500 VA
Watts 900 W
On Battery Voltage 120 VAC ± 5%
On Battery Frequency 60 Hz ± 1%
On Battery Waveform Sine Wave
Outlets - Total 10
Outlets - Battery & Surge Protected 5
Outlets - Surge-Only Protected 5
Overload Protection Internal Circuitry Limiting

Circuit Breaker
Transfer Time 4 ms
USB Charge Yes - Two (2) USB 5V/1A charging ports
Battery
Runtime at Half Load 11 minutes
Runtime at Full Load 2 minutes
Battery Type Sealed Lead-Acid
Battery Size 12V/8.5Ah
Battery Quantity 2
Hot-Swappable No
User Replaceable Yes
Replacement Battery Cartridge RB1280X2B
Replacement Battery Cartridge Quantity 1
Typical Recharge Time 8 hours
Surge Protection & Filtering
Surge Suppression 1,030 J
Coax Protection RG6 1-In, 1-Out
Phone RJ11 / Ethernet RJ45 1-In, 1-Out (Combo)
Management & Communications
HID Compliant USB Port Yes
Serial Port Yes
LED Indicators Power On

Wiring Fault
Audible Alarms On Battery

Low Battery

Overload

Fault
Software PowerPanel® Personal Edition
Multifunction LCD Panel Displays:

Current/Load Level

Runtime

Battery Level

AVR In Use

Battery In Use

Input Voltage

Output Voltage

Output Frequency

Overload

Silent Mode
Management Cable USB Cable
Emergency Power Off (EPO) Port No
Physical
Form Factor Mini-Tower
Dimensions - W×H×D (in) 3.9 × 10.4 × 14.2 inches
Weight (lbs) 24.7 lbs
Environmental
Operating Temperature 32 – 104 °F (0 – 40 °C)
Operating Humidity 0 – 90% (non-condensing)
Certifications
Safety UL1778

cUL 107.3

FCC DOC Class B
Environmental RoHS Compliant
Warranty
Product Warranty 3 Years Limited
Connected Equipment Guarantee Lifetime
CEG Amount $500,000
CP1500PFCLCDTAA | TAA UPS Systems
Federal Trade Agreements Act (TAA) compliant power protection
GreenPower UPS Technology

GreenPower UPS™ Technology from CyberPower consists of three different energy-saving designs that improve operating efficiency, reduce heat generation, and consume less power than conventional UPS models.

ECO Mode: Our ECO Mode is a form of bypass technology that can be switched on full time, set for noncritical times (such as nights and weekends), or switched off. This flexibility can help conserve power and save money.

Bypass Design: Our patented bypass design allows current to bypass the transformer and automatic voltage regulation (AVR) when utility power is normal, thus reducing energy consumption and associated costs. Because utility power functions normally most of the time, the bypass design allows for substantial energy savings. This technology also reduces heat generation, an important factor in decreasing operating costs.

High-Efficiency Design: significantly decreases power consumption to create an ultra-efficient backup battery for home and office use.


Sine Wave Power

In the U.S., utility companies provide power to households and offices by distributing single phase alternating current (AC) power at a frequency of 60 Hz. Electrical power can be graphically depicted as a sine wave whereby the electrical signal alternates from +120 volts to -120 volts at a rate of 60 times per second (60 Hz). To enable more efficient operation of large, heavy equipment, utility companies provide commercial and industrial locations with three phase AC power which consists of three overlapping sine waves offset by 120 degrees.

Although utility companies strive to distribute 100% sine wave power, many factors can introduce electrical noise into the AC power signal in the form of sine wave distortions and as voltage sags, surges, spikes, or other irregularities. Sine wave power is important for the optimal functioning of sensitive desktop computers and related peripheral equipment. Without sine wave power output, microprocessor-based equipment can become inoperative or sustain damage from power signal distortions.


Active Power Factor Correction Supplies for IT Equipment

During the past thirty years, people have become more aware of the amount of energy used by IT equipment and devices. For many years, desktop computers and workstations inefficiently consumed power, partly due to the design of the power supplies which transformed AC power (from the wall outlet) to DC power (used by computers). This voltage transformation was relatively inefficient as reflected in low power factor ratings.

In 1992, the U.S. Environmental Protection Agency (EPA), in collaboration with advocates in the IT industry, developed the ENERGY STAR® program to prompt the development of energy-efficient products. Today this program is recognized as an international standard.

To comply with ENERGY STAR standards, manufacturers of desktop and workstation computers incorporate Active Power Factor Correction (Active PFC) as part of the engineering designs, enabling energy efficiencies of 95% or higher. Computers with Active PFC power supplies require sine wave AC power, as supplied by utility companies, for trouble-free operation. For this reason, sine wave UPS systems have become the best choice for backup power.

Simulated or stepped sine wave power, provided by entry-level UPS systems, may be problematic or incompatible with Active PFC devices. Sine wave power varies continuously from positive to negative. Simulated sine wave power mimics a sine wave by using a squared-off approximation. Due to this approximation, simulated sine wave power momentarily creates a zero power gap. When power is interrupted, a computer with an Active PFC power supply may not recognize incoming simulated sine wave power due to the zero output present in the approximated wave. This could cause the system to unexpectedly shut down or sustain system component stress.

CP1500PFCLCDTAA | TAA UPS Systems
Federal Trade Agreements Act (TAA) compliant power protection

Shutdown software supports most Window systems

Shutdown software for Linux. Requires Linux kernel >2.6.12

Shutdown software for Linux. Requires Linux kernel >2.6.12

View UPS via the USB connection to your Mac

CP1500PFCLCDTAA | TAA UPS Systems
Federal Trade Agreements Act (TAA) compliant power protection
What is the difference between the Battery/Surge outlets and the Surge outlets?

Many CyberPower UPS units have two sets of outlets. One set is labeled "Battery/Surge" and one set is labeled "Surge". The outlets labeled "Battery/Surge" are the outlets that will receive battery power during a power failure. You should plug your computer and monitor into these outlets and any externally powered critical data storage device.

Items such as printers, speakers, scanners, and faxes should be plugged into the outlets labeled "Surge." These outlets are intended for low priority electronics that are not essential to the PC's main operation.

CP1500PFCLCDTAA | TAA UPS Systems
Federal Trade Agreements Act (TAA) compliant power protection
Model Output VA Output Watts Outlets MSRP
CP550SLGTAA 550 VA 330 W 8 NEMA 5-15R $72.95
EC750GTAA 750 VA 450 W 12 NEMA 5-15R $138.95
CP1000PFCLCDTAA 1000 VA 600 W 10 NEMA 5-15R $202.95
CP1500PFCLCDTAA 1500 VA 900 W 10 NEMA 5-15R $304.95
PR1000LCDTAA 1000 VA 700 W 8 NEMA 5-15R $455.95
PR1500LCDTAA 1500 VA 1050 W 8 NEMA 5-15R $529.95
PR1000LCDRT2UTAA 1000 VA 700 W 8 NEMA 5-15R $529.95
PR1500LCDRT2UTAA 1500 VA 1000 W 8 NEMA 5-15R $709.95
PR1500LCDRTXL2UTAA 1500 VA 1125 W 8 NEMA 5-15R $810.95
PR2200LCDRTXL2UTAA 2150 VA 1650 W 8 NEMA 5-15R $1119.95
PR3000LCDRTXL2UTAA 3000 VA 2400 W 7 NEMA 5-15R $1349.95
PR5000LCDRTXL5UTAA 5000 VA 4000 W 7 NEMA 5-15R $2595.95
CP1500PFCLCDTAA | TAA UPS Systems
Federal Trade Agreements Act (TAA) compliant power protection
Ask a CyberPower tech support representative to contact you.



CyberPower Systems values your privacy and your information will never be rented or sold. Information provided will be used for CyberPower's internal use only. View our Privacy Policy.

Please enter the username or email associated with your My CyberPower account.


Thank you! You should receive an email shortly with information on how to change your password.


CyberPower Systems values your privacy and your information will never be rented or sold. Information provided will be used for CyberPower's internal use only. View our Privacy Policy.

Thank you for submitting your information. A CyberPower representative will get in contact with you shortly.


An error has occurred while you were attempting to submit this form - please try again. If the problem persists, please call our sales hotline at 1 (877) 297-6937. Thank you!