OL6000RT3UTFTAA

TAA UPS Systems


OL6000RT3UTFTAA | TAA UPS Systems
Safeguard mission-critical servers, applications, and network equipment with isolated, double-conversion power protection

Product Overview


The CyberPower Smart App Online OL6000RT3UTFTAA is a rack/tower UPS with double-conversion topology and a step-down transformer to support 120V and 200-240V output requirements. It provides sine wave output to mission-critical applications and equipment requiring seamless power protection. This model comes with an extendable LCD control panel, Smart Battery Management charging design, Fast Charge Technology, and energy-saving GreenPower UPS™ ECO Mode. The OL6000RT3UTFTAA offers generator compatibility and delivers clean AC power with zero transfer time. This model can use the BP240V30ART3U Extended Battery Module for expanded runtime and faster restoration of full backup power. The OL6000RT3UTFTAA comes with a three-year warranty and a $300,000 Connected Equipment Guarantee.

  • Data Line Protection
    Prevents power surges that travel through telephone and Ethernet lines from causing damage to electronics.
  • Double-Conversion Topology
    Provides consistent, clean, and nearly perfect power, regardless of the condition of incoming power. Systems with this technology operate on isolated DC power 100% of the time and have a zero transfer time because they never need to switch to battery. Double-conversion UPS systems are designed for high-end system components, corporate servers, lab equipment, and other sensitive electronic devices.
  • Sine Wave Output
    Provides power protection to ENERGY STAR® 6.0 systems with Active PFC power supplies.
  • Step-Down Transformer
    Supports 120V and selectable 200-240V output.
  • Extendable LCD Panel
    Displays UPS statuses and customizable operating settings from up to 10 ft. away (with optional cable). The extendable LCD control panel can be configured in English, Spanish, or French for ease of use.
  • Extended Battery Module (EBM)
    Extends runtime by adding EBMs. This UPS allows for up to ten added modules.
  • Fast Charge Technology
    Allows UPS batteries to return to 100% capacity more rapidly by utilizing a built-in charger inside each EBM. Restores a complete charge within 5 hours regardless of the number of EBMs.
  • Smart Battery Management (SBM)
    Improves and extends the functional life of a UPS battery and reduces excessive heat during work cycles by using a three-cycle charging process.
  • GreenPower UPS™ ECO Mode
    Improves UPS efficiency up to 95%; saves on electrical and cooling costs.
  • Hot-Swappable Batteries
    Eliminate downtime related to UPS power maintenance for continuous power availability.
  • Critical & Non-Critical Loads
    The UPS has two banks of outlets which can be configured so that the non-critical loads shut off after a set timeframe to provide additional runtime for the critical load outlet. Users can prioritize their equipment runtimes to maximize the output of the UPS to meet their power requirements.
  • Emergency Power Off (EPO)
    Allows the UPS to be shut off in the event of an emergency, when the EPO port is connected to an EPO switch.
  • Backfeed Protection
    Prevents the risk of electric shock from any electric current feeding back from the UPS through the input terminals when utility power is lost. Backfeed protection isolates the UPS and allows service personnel to safely work on the utility power.
  • Generator Compatible
    Provides stable sine wave output (free of harmonics and distortion) without switching to battery mode when running on generator input power.
  • Converter Mode
    Provides the flexibility to set the output frequency, regardless of the input frequency, to match connected equipment by selecting 50Hz or 60Hz output on the LCD control panel.
  • USB & Serial Connectivity
    Enables full integration with built-in power management and auto shutdown features on Windows, Linux, and VMware systems through a HID-compliant USB port and Serial port.
  • EMI/RFI Filters
    Prevent electromagnetic and radio frequency interference to ensure clean power for connected equipment.
  • Audible Alarms
    Identify when the model is running on battery power, overloaded, or has a low battery.
  • Resettable Circuit Breaker
    Interrupts an electric current in a circuit when the current becomes too high.
  • LED Status Lights
    Indicate Power On, Line Mode, Battery Mode, Bypass Mode, Fault, Replace Battery.
  • Rack/Tower Versatility
    Allows for horizontal rack or vertical tower installation.
  • PowerPanel® Business Edition Software
    Provides IT professionals with tools for monitoring and managing the UPS and backup power. This software offers remote management functionality. Free software download available. See the Resources tab.
  • Cisco Compatible
    This CyberPower UPS system is a Cisco EnergyWise compliant end device.
  • ENERGY STAR
    This model is an ENERGY STAR® certified Uninterruptible Power Supply (UPS) system. ENERGY STAR is the trusted, government-backed symbol for energy-efficient products and practices that help save money and protect the environment.
  • Three-Year Warranty
    CyberPower will repair or replace a defective UPS system (including batteries) within three years of the purchase date. See warranty for details.
  • Connected Equipment Guarantee
    CyberPower will repair or replace properly connected equipment if it is damaged by a power surge.

What's In The Box

Power Module, Battery Module, STF Module, 2 User Manuals, USB Device Cable, Telephone Cable, Serial Cable, 2 Warranty Registration Cards, PowerPanel Business Edition Software CD, 3 Rackmount Rails (left & right), 6 Rackmount Ears (stands), 2 Tie Plates, 24 Flat Head Screws (M5X8L), 36 Pan Head Screws (M5X12L), 24 Plastic Washers, 30 Screw Hole Dust Covers, Power Cord

OL6000RT3UTFTAA | TAA UPS Systems
Safeguard mission-critical servers, applications, and network equipment with isolated, double-conversion power protection
General  
UPS Topology Double-Conversion
Energy Saving ECO Mode Efficiency >95%
Input  
Voltage 200 – 240 VAC
Input Voltage Range 120 – 139 VAC for 0–25% load

140 – 159 VAC for 0–50% load

160 – 179 VAC for 0–75% load

180 – 280 VAC for 0–100% load
Frequency Range 40 – 70 Hz
Input Power Factor 0.99
Cold Start Yes
Plug Type NEMA L6-30P
Cord Length 10 ft
Backfeed Protection Yes
Output  
VA 6,000 VA
Watts 5,400 W
On Battery Voltage 120 VAC ± 2%

Configurable to 200, 208, 220, 230 & 240 VAC ± 2%
On Battery Frequency 50/60 Hz ± 0.25 Hz (auto-sensing or configurable)
On Battery Waveform Sine Wave
Outlet Type NEMA L6-30R (1),

NEMA L6-20R (2),

NEMA 5-20R (12)
Outlets - Total 15
Rated Power Factor 0.9
Crest Factor 3:1
Harmonic Distortion THD < 3% at Linear Load, < 5% at Non-linear Load
ECO Mode Voltage Regulation ±10%, ±15% (Configurable)
Bypass Internal Bypass (Automatic and Manual)
Overload Protection Battery Mode: 105~130% Load for 10 sec,

Battery Mode: 131~150% Load for 2 sec ,

Line Mode: 126~150% Load for 10 sec,

Line Mode: 105~125% Load for 1 min
Transfer Time 0 ms
Battery  
Runtime at Half Load 15.8 minutes
Runtime at Full Load 5.3 minutes
Battery Type Sealed Lead-Acid
Battery Size 12V/7.2Ah
Battery Quantity 20
Hot-Swappable Yes
User Replaceable Yes
Replacement Battery Cartridge RB1272X20
Replacement Battery Cartridge Quantity 1
Typical Recharge Time 4 hours (2.5 w/Fast Charge Technology)
Extended Battery Option BP240V30ART3U
Smart Battery Management (SBM) Mode Yes
Surge Protection & Filtering  
Surge Suppression 2,670 J (IEC 61000-4-5 Level 3)
EMI/RFI Filtration Yes
Phone / Network Protection RJ11/RJ45 1-In / 1-Out
Management & Communications  
LCD Control Panel 38 different settings/options via the UPS Status menu, UPS Setup menu, and run Testing menus.
Removable LCD Control Panel Option Yes - Requires a separate DB26 Cable
HID Compliant USB Port Yes
Serial Port Yes
EPO Port Yes
Dry Contacts Yes
Management Cable USB Cable, Serial Cable
LED Indicators Power On (white)

Line Mode (green)

Battery Mode (yellow)

Bypass Mode (yellow)

Fault (red)

Replace Battery (red)
Audible Alarms Battery Mode

Battery Low

Overload

UPS Fault

Replace Battery
Software PowerPanel® Business Edition
SNMP / HTTP Remote Monitoring Yes, with optional RMCARD302 or RMCARD303
Physical  
Form Factor Rack/Tower
Enclosure Contruction Steel
Mounting Hardware Included
Physical - Power Module  
Dimensions - W×H×D (in) 17 × 5.25 × 26 inches
Dimensions - W×H×D (mm) 433 × 132 × 660 mm
Weight (lbs) 55 lbs
Weight (kg) 24.95 kg
Power Module Rack Height 3U
Physical - Battery Module  
Dimensions - W×H×D (in) 17 × 5.25 × 26 inches
Dimensions - W×H×D (mm) 433 × 132 × 660 mm
Weight (lbs) 167.2 lbs
Weight (kg) 76 kg
Battery Module Rack Height 3U
Physical - Power Module, Battery Module & Step-down Transformer  
Dimensions - W×H×D (in) 17 × 14 × 26 inches
Dimensions - W×H×D (mm) 433 × 355.6 × 660 mm
Weight (lbs) 348.3 lbs
Weight (kg) 158.3 kg
Installed Rack Height 8U
Step-down Transformer  
Dimensions - W×H×D (in) 17 × 3.5 × 26 inches
Dimensions - W×H×D (mm) 433 × 88.9 × 660 mm
Weight (lbs) 128.3 lbs
Weight (kg) 58.3 kg
Installed Rack Height 2U
Power Module, Battery Module, Step-Down Transformer (Shipping Dimensions)  
Dimensions - W×H×D (in) 23.62 × 38.1 × 35.43 inches
Dimensions - W×H×D (mm) 600 × 968 × 900 mm
Weight (lbs) 440 lbs
Weight (kg) 200 kg
Environmental  
Operating Temperature 32 – 104 °F (0 – 40 °C)
Operating Humidity 0 – 90% (non-condensing)
Operating Elevation 0 – 10,000 ft (0 – 3,000 m)
Storage Temperature 5 – 113 °F (-15 – 45 °C)
Storage Relative Humidity 0 – 95% (non-condensing)
Storage Elevation 0 – 50,000 ft (0 – 15,000 m)
Online Thermal Dissipation 2,048 BTU/hr
Audible noise at 1.5M from surface of unit 55 dBA
Certifications  
Safety UL1778

CSA C22.2 NO.107.3-05

FCC DOC Class A
Environmental RoHS Compliant
Warranty  
Product Warranty 3 Years Limited
Connected Equipment Guarantee Lifetime
CEG Amount $300,000
OL6000RT3UTFTAA | TAA UPS Systems
Safeguard mission-critical servers, applications, and network equipment with isolated, double-conversion power protection
Battery Technology

Fast Charge Technology and Smart Battery Management (SBM) prolong the capacity and life of a UPS battery. This provides greater efficiency and fewer battery replacements.

Fast Charge Technology enables the backup power supply to more quickly return to full capacity (100%) because each Extended Battery Module attached to the UPS uses its own charger. Typical systems share only a single charger for all attached battery modules, which increases the time required to fully restore backup power.

Smart Battery Management (SBM) charges a UPS battery in three phases, extending its functional life. SBM also reduces the heat produced by a UPS battery and reduces battery deterioration.


Extendable LCD Control Panel

Often a UPS is installed in a hard-to-reach area, such as a crowded IT closet, the bottom of a rack, or on the floor. A removable LCD control panel allows for easy access and can be placed up to ten feet away from the UPS when connected by a DB26 cable (sold separately).

Menu Functions

UPS Status displays vital information about the UPS. There are 19 status types, including input and output voltage, battery information, runtime estimates, load data, and more.

LCD Settings Configuration offers customization of the UPS with 38 specific operation parameters including output voltage, sync frequency, alarm settings, and more.

Event Log allows for recording of UPS events with or without PowerPanel® Business Edition management software.

Multi-Language (select models) provides options to display text in English, Spanish, French, or German.

Disable Audible Alarms turns off audible alarms, as needed.

Manual Battery Test enables user to run a UPS system test to ensure proper operation.


Higher Capacity UPS for Longer Runtimes

To determine the size of the UPS that you need, identify the total power load (measure in VA/Watts) of the connected equipment, along with the amount of runtime required (in minutes). Also, think about any equipment that might be connected to the UPS in the future, which could affect the calculations for load and runtime.

Estimating expected UPS runtimes can be challenging, particularly when the consistency of the utility power is not well known. Selecting a UPS with a load capacity 30-35% above the required power load offers the advantage of longer runtimes. This can lower the risk of overloading the UPS and causing an unnecessary UPS shutdown.

Although the initial outlay of a UPS increases with its size because of the higher capacity required for components, long-term operating costs typically decrease. When a UPS operates below maximum capacity, it reduces the stress on components. Sizing a UPS to run loads significantly lower than its capacity also increases spare capacity for future growth, along with extending runtimes.

OL6000RT3UTFTAA | TAA UPS Systems
Safeguard mission-critical servers, applications, and network equipment with isolated, double-conversion power protection

Shutdown software supports most Window systems

Shutdown software supports most Linux and XenServer

Shutdown software supports most Linux, XenServer, ESX, ESXi

Shutdown software supports VMWARE vSphere, ESXi 4.1 and later

Shutdown software supports VMWARE vSphere, ESXi 4.1 and later

Shutdown software supports most Mac systems

OL6000RT3UTFTAA | TAA UPS Systems
Safeguard mission-critical servers, applications, and network equipment with isolated, double-conversion power protection
What is the difference between the Battery/Surge outlets and the Surge outlets?

Many CyberPower UPS units have two sets of outlets. One set is labeled "Battery/Surge" and one set is labeled "Surge". The outlets labeled "Battery/Surge" are the outlets that will receive battery power during a power failure. You should plug your computer and monitor into these outlets and any externally powered critical data storage device.

Items such as printers, speakers, scanners, and faxes should be plugged into the outlets labeled "Surge." These outlets are intended for low priority electronics that are not essential to the PC's main operation.

OL6000RT3UTFTAA | TAA UPS Systems
Safeguard mission-critical servers, applications, and network equipment with isolated, double-conversion power protection
Model Output VA Output Watts Outlets MSRP
CP550SLGTAA 550 VA 330 W 8 NEMA 5-15R $72.95
EC750GTAA 750 VA 450 W 12 NEMA 5-15R $138.95
CP1000PFCLCDTAA 1000 VA 600 W 10 NEMA 5-15R $202.95
CP1500PFCLCDTAA 1500 VA 900 W 10 NEMA 5-15R $304.95
PR1000LCDTAA 1000 VA 700 W 8 NEMA 5-15R $455.95
PR1500LCDTAA 1500 VA 1050 W 8 NEMA 5-15R $529.95
PR1000LCDRT2UTAA 1000 VA 700 W 8 NEMA 5-15R $529.95
PR1500LCDRT2UTAA 1500 VA 1000 W 8 NEMA 5-15R $709.95
PR1500LCDRTXL2UTAA 1500 VA 1125 W 8 NEMA 5-15R $810.95
PR2200LCDRTXL2UTAA 2150 VA 1650 W 8 NEMA 5-15R $1119.95
PR3000LCDRTXL2UTAA 3000 VA 2400 W 7 NEMA 5-15R $1349.95
PR5000LCDRTXL5UTAA 5000 VA 4000 W 7 NEMA 5-15R $2595.95
OL6000RT3UTFTAA | TAA UPS Systems
Safeguard mission-critical servers, applications, and network equipment with isolated, double-conversion power protection
Ask a CyberPower tech support representative to contact you.



CyberPower Systems values your privacy and your information will never be rented or sold. Information provided will be used for CyberPower's internal use only. View our Privacy Policy.

Please enter the username or email associated with your My CyberPower account.


Thank you! You should receive an email shortly with information on how to change your password.


CyberPower Systems values your privacy and your information will never be rented or sold. Information provided will be used for CyberPower's internal use only. View our Privacy Policy.

Thank you for submitting your information. A CyberPower representative will get in contact with you shortly.


An error has occurred while you were attempting to submit this form - please try again. If the problem persists, please call our sales hotline at 1 (877) 297-6937. Thank you!