PDU20MHVT10AT


Metered ATS PDU Series

MSRP $425.00

  • Digital meter: Displays Amperage, Voltage, & Kilowatts
  • Phase: Single
  • Amps: 20A (Derated to 16A)
  • Volts: 200 – 240 V
  • Plug type: 2 x NEMA L6-20P
  • Outlets: 10 IEC-320 (8) C13 / (2) C19 Outlets
  • Size: 1U Rackmount
  • Dimensions (in.): 17.05W x 1.75H x 9.30D
  • Cord length (ft.): 10
  • SNMP/HTTP: Optional
  • Warranty: 3 year
Categories: ,

Product Description

PDU20MHVT10AT | Metered ATS PDU Series
Deliver and monitor reliable, redundant power to electronic equipment, servers, and network/telecom devices

Product Overview


The CyberPower PDU20MHVT10AT, a 10-outlet (rear), 1U rackmount metered auto transfer switch (ATS) power distribution unit (PDU), provides 200-240V 20A output. The PDU distributes unfiltered electrical pass-through to 10 IEC-320 (8) C13 / (2) C19 receptacles from redundant NEMA L6-20P plugs. Dual power cords can be plugged into separate power sources to provide redundancy to single-corded connected equipment. If power for the primary source exceeds the lower or upper thresholds, or if power fails, the PDU will switch to the secondary power source to ensure continuous operation. The PDU will switch back to the primary power source when incoming power becomes stable. The current draw for connected equipment is displayed in amps on the front LCD for real-time load monitoring.

Designed for datacenters and other demanding electrical applications, the PDU20MHVT10AT has rugged, industrial-grade metal housing and a 10-foot AC power cord, and a cord retention tray. It can be mounted horizontally. The PDU20MHVT10A comes with a cord retention tray and is UL and CSA certified by ETL. A three-year limited warranty covers the PDU for three years and connected equipment for as long as you own the product.

  • Power Distribution
    Delivers AC power to servers, equipment, and connected devices via a power distribution unit.
  • Automatic Transfer Switch
    Dual power cords (A & B) provide redundant power sources to devices with single power supplies and can be plugged into separate compatible sources* to ensure continuous access. Users select the preferred source as the primary input. CyberPower Smart App Online and Sinewave series UPS are highly recommended for use as the power source.
    *Note: Only sine wave AC power sources are compatible with this ATS PDU. Simulated sine wave AC power sources are NOT compatible.
  • LCD Screen
    Provides real-time meter status for current (amperes), input and output voltages, power consumptions (kilowatts), and hardware/firmware versions.
  • Upgradeable Hardware & LCD Firmware
    Are updatable to the latest versions by using the serial communication port and included cable.
  • Serial Communication Port & Cable
    Used to update/upgrade the hardware and LCD firmware.
  • SNMP/HTTP Card Slot
    Accepts an RMCARD205 (sold separately), providing remote monitoring, reporting, and event notifications, via Email, SMS Text, or SNMP Trap.
  • Protocol Support
    With installation of an RMCARD205 (sold separately), the metered ATS PDU provides protocol support for PowerPanel Business Edition, HTTP, TCP/IP, UDP, DHCP, and SNMP including SNMPv3, IPv4, IPv6, NTP, SMTP protocols.
  • Network-Grade Plugs and Outlets
    Highly durable construction ensures the efficient distribution of power in demanding IT or industrial environments to servers, equipment, and connected devices.
  • Rackmounting Brackets
    Allow for 1U horizontal rack installation.
  • Cord Retention Tray
    Secures power cords, keeping them organized and accessible. Helps cords stay plugged in.
  • Three-Year Limited Warranty
    Covers the PDU for three years and connected equipment for as long as you own the product. See warranty for details.
What’s In The Box

ATS PDU, 2 Mounting Brackets, 24 M4x8 Bracket Mounting Screws, 6 M5x12 Rack Mounting Screws, 6 Washers, Cord Retention Tray, 2 M3x4 Cord Retention Tray Mounting Screws, 18 Cable Ties, RJ45/DB9 Serial Port Connection Cable, User Manual, Registration Card, 2 IEC Socket Power Cord Stands, 15 M3x4 Screws, 18 Power Cord Retention Cable Clip, 18 Cable Ties

PDU20MHVT10AT | Metered ATS PDU Series
Deliver and monitor reliable, redundant power to electronic equipment, servers, and network/telecom devices
Input
Nominal Input Voltage200 – 240 VAC
Frequency50/60 Hz
Maximum Current20A (derated to 16A)
Plug Type2 × L6-20P
Plug StyleStraight, Twist Lock
Cord Length10 ft
Output
Nominal Output Voltage200 – 240 VAC
Outlet Banks1
Outlets – Total10
Outlets – Front0
Outlets – Rear10
Outlet TypeIEC-320 (8) C13 / (2) C19
LCD ReadoutKW
Voltage
Amperage
Network Information
HW/FW Version
LED IndicatorsInput
Output Load
Communication
SNMP / HTTP Remote MonitoringOptional RMCARD205
ConnectivitySerial (RJ45)
Physical
Dimensions – H×W×D (in)17.05 x 1.75 x 9.30 inches
Rack Size1U
Weight (lbs)11.46 lbs
StyleRackmount
Form Factors Supported1U rackmount
Cord Retention Tray/Cord OrganizersYes
Adjustable Mounting Brackets1 set (L-long)
External Site Ground PinYes
Environmental
Operating Temperature32 – 113 °F (0 – 45°C)
Operating Humidity0 – 95% (non-condensing)
Maximum Operating Elevation13,100 ft (4,000 m)
Storage Temperature5 – 113 °F (-15 – 45°C)
Maximum Storage Elevation50,000 ft (15,000 m)
Certifications
SafetyUL60950_1 certified by ETL
CSA C22.2
FCC Class A
EnvironmentalRoHS Compliant
Warranty
Product Warranty3 year
PDU20MHVT10AT | Metered ATS PDU Series
Deliver and monitor reliable, redundant power to electronic equipment, servers, and network/telecom devices
Understanding PDUs

Power Distribution Units (PDUs) by CyberPower are engineered to distribute reliable network power to multiple devices. A PDU does not generate conditioned power, but delivers AC power from a UPS (uninterruptible power supply), a generator, or utility power source to servers, network/telecom equipment, and other devices. Selecting the best PDU for your needs depends on the output voltage required, the number of outlets needed for connected devices, plug and outlet types, and mounting options.

Versatile. CyberPower PDUs are designed with as many as 38 outlets. Offered in 0U, 1U, and 2U form factors, each PDU includes the necessary hardware to be mounted vertically or horizontally inside densely configured rack enclosures. The PDU can also be mounted on a wall or under a shelf.

Scalable. In smaller networks, conditioned power can be distributed through a single PDU from a UPS, while a complex data center might require the connection of multiple PDUs to a large-capacity UPS system.


Different PDU Series for Different Needs

CyberPower offers multiple offerings of power distribution units (PDUs): Basic, Metered, Metered ATS, Monitored, Switched, Switched ATS and Maintenance-Bypass. Each series serves a specialized purpose. Models within the same series have similar features and capabilities.

Basic: Reliable and unfiltered AC power distribution from a UPS system, generator, and/or utility source to multiple connected devices.

Metered: Network-grade power distribution plus load meters (amps) to prevent overloads and safely optimize load levels.

Monitored: Network-grade power distribution with remote monitoring through an SNMP network interface and local management via a digital meter display to prevent downtime due to overloads or other power events.

Switched: Intelligent, network-grade power distribution and the ability to control outlets individually or collectively to solve power issues such as shutdowns or to plan scheduled rebooting. A digital meter provides information on load and voltage, as well as local control of the outlets. An SNMP connection enables remote monitoring and control of the outlets to ensure complete control regardless of location.

Switched Metered-by-Outlet: Monitor the power consumption of individual outlets in real-time over the network, or locally using the PDU’s interactive digital display. Outlets can be switched on and off remotely for unscheduled reboots, automated load shedding, controlled power-cycling and more.

Metered ATS: Redundant NEMA plugs. Dual power cords can be plugged into separate power sources. If power for the primary source exceeds the lower or upper thresholds, or if power fails, the PDU will switch to the secondary power source to ensure continuous operation.

Switched ATS: Individual management of switched outlet receptacles. Remote and local control of outlets. Redundant NEMA plugs. Dual power cords can be plugged into separate power sources. If power for the primary source exceeds the lower or upper thresholds, or if power fails, the PDU will switch to the secondary power source to ensure continuous operation.

Maintenance-Bypass: Maintenance Bypass PDUs allow the seamless transfer of an electrical load from UPS power to utility power for uninterrupted operation of connected equipment when performing maintenance, replacing batteries, or installing a new UPS.


PDU20MHVT10AT | Metered ATS PDU Series
Deliver and monitor reliable, redundant power to electronic equipment, servers, and network/telecom devices

Find the PDU/RMCARD's IP Address

Upgrade firmware and/or configure multiple CyberPower RMCARDs or monitored, switched PDUs at once.

Switched / Metered ATS Hardware v1.0

Switched / Metered ATS Hardware v1.0

PDU20MHVT10AT | Metered ATS PDU Series
Deliver and monitor reliable, redundant power to electronic equipment, servers, and network/telecom devices
Do any of the CyberPower PDUs have an on/off switch?

No. None of the PDUs will have on/off switches on them. All CyberPower PDUs are always on by design.

Our Technical Support team will be happy help you with technical questions during business hours.

Chat Live
Monday - Friday
7am — 6pm CST

CHAT NOW

Email
Monday - Friday
7am — 6pm CST
tech@cpsww.com

Call Toll Free
Live Monday - Friday
7am — 6pm CST
1-877-297-6937 ( press 1 )

Ask a CyberPower tech support representative to contact you.



CyberPower Systems values your privacy and your information will never be rented or sold. Information provided will be used for CyberPower's internal use only. View our Privacy Policy.

PDU20MHVT10AT | Metered ATS PDU Series
Deliver and monitor reliable, redundant power to electronic equipment, servers, and network/telecom devices
     ModelVoltageCord LengthRacksizeCurrentInput PlugOutlets MSRP
     PDU15M10AT 100 – 120 VAC10 ft1U15 A (derated to 12 A)2 x NEMA 5-15P10 x NEMA 5-15R $356.00
     PDU20M10AT 100 – 120 VAC10 ft1U20 A (derated to 16 A)2 x NEMA 5-20P10 x NEMA 5-20R $449.00
     PDU20MT10AT 100 – 120 VAC10 ft1U20 A (derated to 16 A)2 x NEMA L5-20P10 x NEMA 5-20R $463.00
     PDU15MHVIEC12AT 200 – 240 VAC10 ft1U15 A (derated to 12 A)2 x IEC-320 C1412 x IEC-320 C13 $395.00
     PDU20MHVIEC10AT 200 – 240 VAC10 ft1U20 A (derated to 16 A)2 x IEC-320 C202 x IEC-320 C19, 8 x IEC-320 C13 $445.00
     PDU20MHVT10AT 200 – 240 VAC10 ft1U20 A (derated to 16 A)2 x L6-20P2 x IEC-320 C19, 8 x IEC-320 C13 $425.00
     PDU30MT17AT 100 – 120 VAC10 ft2U30 A (derated to 24 A)2 x NEMA L5-30P1 x NEMA L5-30R, 16 x NEMA 5-20R $619.00
     PDU30MHVT19AT 200 – 240 VAC10 ft2U30 A (derated to 24 A)2 x L6-30P16 x IEC-320 C13, 2 x IEC-320 C19 $642.00
    PDU20MHVT10AT | Metered ATS PDU Series
    Deliver and monitor reliable, redundant power to electronic equipment, servers, and network/telecom devices